Skip to main content

Your Emissions in control

Modification pressure vessel - scrubber

Modification pressure vessel

The lifetime of a pressure vessel was reached due to chemical attack of the reactive fluid inside the vessel. Array industries removed part of the vessel at site, re-built the top part with chemical resistant material and installed the top part at site. The work was executed under Lloyds approval.

 

Challenge

The challenge for Air Liquide was to stretch the life of the pressure vessel.

Solution

This pressure vessel modification consists of replacing 7 meters of P355 scale for a SS316L scale. We removed the existing scrubber (plasma cutting), modified the scrubber in our workshop and installed the new scrubber section on site using a gold welding method. This means that the weld is examined using two different NDT methods. Complete project management, safety plan, transport and lifting were part of our scope of delivery.

Facts

Pollution control

Customer:

Air Liquide

Location:

Maasvlakte Rotterdam, the Netherlands

Benefits

Safe operation thanks to amine-resistant pressure vessel

Solutions:

Gas-scrubber, Stack

ARRAY

Hoogeveenenweg 93
2913 LV Nieuwerkerk aan den IJssel

Nederland

This email address is being protected from spambots. You need JavaScript enabled to view it.
+31 (0) 10 765 12 00

 

LINKS

Privacy statement

 